A complete list of all of the possible module System Controller messages is provided in Table C-1.
Table C-1. MSC Alpha-Numeric Display Messages
MSC Message | Meaning |
---|---|
CHK INV | The current system configuration is different than the stored hardware inventory. Run “update” to eliminate this message. |
FAN FAIL | A system fan has failed. If it is fan 1, 2, or 3, the system shuts down. A service call should be placed as soon as possible. |
HBT TO | The system has registered a heart beat time-out. A non-maskable interrupt is generated, followed by a system reset. |
KEY OFF | The MSC keyswitch has been turned to standby. |
M FAN FL | More than one fan has failed and the system has shut down. |
NMI | The MSC keyswitch has been turned to the diagnostic position, and the non-maskable interrupt (NMI) button has been pushed. |
OVR TEMP | The system's temperature has exceeded acceptable limits and the system has shut down. |
PFW FAIL | The power supplied to the system has failed or dropped below acceptable parameters. The system has shut down. |
POK FAIL | A power OK failure occurred on an unidentified board. |
POWER UP | The system is being powered on from the front panel switch. |
PS OT FL | The system's power supply temperature has exceeded safety limits and the system has shut down. |
PS FAIL | The internal power supply has failed and the system has shut down. |
PWR CYCL | The MSC has received the command to power cycle from the console or a remote user. |
R PWR DN | The system is being powered off remotely via the MSC serial connection (typically by an MMSC). |
R PWR UP | The system is being powered on remotely via the MSC serial connection (typically by an MMSC). |
RESET | The MSC keyswitch has been turned to the diagnostic position, and the reset button has been pushed. |
SYS OK | The system is operating normally. |